VMware: Support for vSAN Datastores

https://blueprints.launchpad.net/nova/+spec/vmware-vsan-support

Currently the vmwareapi compute driver only supports deploying instances to NFS and VMFS datastores. This blueprint proposes to add support for using vSAN storage as well.

Explanation of terminology used:

The term “datastore” as referred to in the spec and the driver refers to the vSphere concept a logical storage container, a place where VM data (among other things) is kept. The purpose of this abstraction is to provide a uniform way for vSphere clients to access said VM data regardless of what hardware, I/O protocols or transport protocols are used by the underlying storage.

All vSphere datastores until recently has been broadly divided into two types, VMFS and NFS. The vmwareapi driver has been supporting the use of both since its inception, without having to distinguish between either, largely because of this datastore abstraction.

vSAN storage is a third type of datastore introduced in vSphere. It is a software-defined distributed storage that aggregates disks (magnetic for capacity, SSD for cache/performance) attached to a group of hosts into a single storage pool. That pool is once again exposed as a single datastore.

Problem description

Currently datastores with type “vsan” is ignored by compute driver entirely. One obstacle to using this type of datastore is that virtual disk data files (the “-flat.vmdk” files) are not directly addressable as datastore paths. Since both the spawn and snapshot workflow in the vmware driver addresses the data files in some way, they will have to be changed to support vSAN datastores.

Use Cases

The End User will be able to use vSAN datastores and deploy streamOptimized images.

Project Priority

None

Proposed change

The change is divided into two areas:

  • Recognize and use datastores of a new type (“vsan”).

  • Update existing code involved in exporting and importing Glance images to use alternate vSphere APIs that does not address disk data files directly.

The second area of change is mainly provided by the image-transfer functionality in the oslo.vmware library [*]. The proposal is to update the code to use said library.

However, the only disk format that these alternate APIs support is the ‘streamOptimized’ format. (The streamOptimized format is a sparse, compressed, and stream-friendly version of the VMDK disk that is well suited for import/export use cases, such as the glance<->hypervisor exchanges described above). This implies that only streamOptimized disk images are deployable on vSAN. The driver will be modified to recognize Glance vmdk images tagged with the property vmware_disktype=’streamOptimized’ as disks of such format, and only use the alternate APIs when handling disks of this format.

Alternatives

None.

Data model impact

None

REST API impact

None

Security impact

None

Notifications impact

None

Other end user impact

None

Performance Impact

None

Other deployer impact

There is a new configuration option under the [vmware] section, “image_transfer_timeout_secs”, which configures how long an image transfer can proceed before timing out.

In order to deploy existing VMDK images to vSAN, these images will have to be converted to streamOptimized and reimported to glance.

Developer impact

Minimal. The changes related to blueprint are mostly isolated in the areas of handling a new vmdk format type and add recognition and use of an additional datastore type called “vsan”.

Implementation

Assignee(s)

Primary assignee:

rgerganov

Work Items

The work is broadly decomposed into:

  • use oslo.vmware image_transfer module to handle download of images

  • use oslo.vmware image_transfer module to handle upload of image snapshot

  • update driver to allow the use of datastores of type vSAN.

  • update driver to recognized a new vmdk format (streamOptimized)

Dependencies

None

Testing

Since Tempest in general does not support driver-specific tests, the proposal is to update the MineSweeper CI (https://wiki.openstack.org/wiki/NovaVMware/Minesweeper), to provide vCenter with vSAN storage and additional tests to verify existing Tempest tests passes when invoked against compute nodes using it.

Documentation Impact

New information in the vmware driver section of the Nova documentation will have to be added to document:

  • How to configure a compute node for vSAN use.

  • The virtual disk format requirement (“streamOptimized” only) when using vSAN storage.

  • The new “image_transfer_timeout_secs” configuration option.

  • How to obtain a streamOptimized disk from a virtual machine or vmdk disk in a non-streamOptimized format.

References