Efficient volume copy for volume migration¶
https://blueprints.launchpad.net/cinder/+spec/efficient-volume-copy-for-cinder-assisted-migration
Currently, cinder supports these 3 ways for volume migration.
#
Migration method
Data copy method
Handler of migration
1
storage driver
depend on vendor storage
inside storage array
2
copy_volume_data()
dd command
cinder volume node
3
swap_volume()
libvirt block rebase copy
nova compute node
During volume migration case #2, Cinder uses dd command for data copy of volume migration, but the copy always copies full blocks even if the source data contains many null and zero blocks. The dd command has an option conv=sparse to skip null or zero blocks for more efficient data copy.
The purpose of this request is to introduce a mechanism to handle sparse copy option properly for volume migration using dd command.
Problem description¶
If we create a volume from thin-provisioning pool, volume blocks are not pre-allocated, and the volume blocks will be allocated on demand. In this situation, if we migrate detached volume using dd command, dd will copy full block from source to destination volume even if the source volume contains many null or zero blocks. As a result, usage of the destination volume will be always 100%. Here is an example volume migration using thin LVM driver.
Before migration
LV VG Attr LSize Pool Origin Data%
vg1-pool vg1 twi-a-tz-- 3.80g 10.28
volume-1234 vg1 Vwi-a-tz-- 1.00g vg1-pool 19.53
After migration without conv=sparse option
LV VG Attr LSize Pool Origin Data%
vg2-pool vg2 twi-a-tz-- 3.80g 31.45
volume-1234 vg2 Vwi-a-tz-- 1.00g vg2-pool 100.00
Use Cases¶
Using sparse copy is able to reduce volume usage of destination storage array compared to using full block copy.
Proposed change¶
If the volume pre-initilization(zero cleared) is ensured beforehand at the destination c-vol, we can skip copy of null and zero blocks to destination volume by using conv=sparse option for dd.
However, if the destination volume is not zero cleared beforehand, we should disable sparse copy and copy full block from source to destination volume to avoid data corruption problem.
For example, following case, we should disable sparse copy and copy full block because new volume of thick LVM might not be initialized, we must not use conv=sparse option for similar cases.
Source c-vol driver: Thin LVM
Dest c-vol driver: Drivers who provides an uninitialized new volume. (ex. Thick LVM)
In order to handle sparse option properly, following changes are required.
Add cinder_sparse_copy_volume capability into capabilities list as a well-defined option.
'cinder_sparse_copy_volume': {
'default': 'False',
options: {}
},
Get capability list from the “destination cinder volume driver” using
get_capabilities
method before starting volume copy.
get_capabilities
method is proposed following Spec.
Updating Get Volume Driver Capabilities Spec: https://review.openstack.org/#/c/183947/1
These are steps of migrate_volume related to sparse copy.
source c-vol driver dest c-vol driver
| |
| ========================================> |
| Ask capability of sparse copy via |
| get_capabilities |
| <======================================== |
| Dest c-vol returns capabilities to |
| source c-vol |
| ========================================> |
| Start volume copy with or without sparse |
| based on the retun from dest c-vol |
| |
Alternatives¶
Copy full blocks from source volume to destination volume. And then, try fstrim or blkdiscard to release unused blocks to backend storage. However, if the backend storage doesn’t support UNMAP SCSI command, we can’t release unused blocks after migration.
Data model impact¶
None
REST API impact¶
Add cinder_sparse_copy_volume parameter as a well_defined capability.
'cinder_sparse_copy_volume': {
'default': 'False',
options: {}
},
Security impact¶
None
Notifications impact¶
None
Other end user impact¶
None
Performance Impact¶
This feature improves required time to copy data between source and destination volume.
Other deployer impact¶
None
Developer impact¶
None
Implementation¶
Assignee(s)¶
- Primary assignee:
mitsuhiro-tanino
Work Items¶
Add cinder_sparse_copy_volume capability into capabilities list.
Add handler of get_capabilities in migrate_volume method.
Update LVM reference implementation with cinder_sparse_copy_volume capability.
Update NFS driver with cinder_sparse_copy_volume capability:
NFS driver already has _sparse_copy_volume_data option but this way doesn’t ask capability to destination cinder volume before volume copy. We should use same way to handle sparse copy.
Dependencies¶
None
Testing¶
Unit tests
Documentation Impact¶
Need to update openstack cloud administrator guide. http://docs.openstack.org/admin-guide/blockstorage_volume_migration.html
References¶
Related Cinder Spec
Updating Get Volume Driver Capabilities Spec: https://review.openstack.org/#/c/183947/1
Related fix